Welcome To HONDEE

360 4IN1 IPL OPT HAIR REMOVAL MACHINE

Short Description:

At a time when people’s living standards are constantly improving and medicine is advancing rapidly, the study of cellular medicine has made great progress every day. For 5,000 years, humans have used natural herbs or chemicals to stimulate the body’s self-healing mechanism.


Product Detail

Product Tags

Preface

At a time when people's living standards are constantly improving and medicine is advancing rapidly, the study of cellular medicine has made great progress every day. For 5,000 years, humans have used natural herbs or chemicals to stimulate the body's self-healing mechanism. However, since then, human medical concepts of the body have gradually changed to the use of cell differentiation techniques, transforming general cells into stem cells, separating protocells from stem cells, and injecting protocells into damaged tissues for redifferentiation. Give birth to new cells to replace cells in damaged areas, rebuild new organs, achieve the ideal organ operation, and regain the health of the body.

Beauty salons are also constantly catching up with the trend of self-improvement to meet the new awareness of customers, new pursuit. Only in this way can the reputation, grade, and popularity of beauty salons be improved. The storefront will be able to hold on to old customers and attract more new customers and more market share.

There are many kinds of so-called advanced beauty instruments on the market today. How many are really effective? Remarkable curative effect is also less, and beauty instruments market fish and fish mixed beads, many beauty salons want to catch up with fashion trends, but also afraid of being deceived also do not want to pay more. The OPT repair physiotherapy instrument we produced is the most advanced combination of perfect photons and radio frequency in the world. Its core technology is: perfect photon system + radio frequency system + epidermal cooling system.In the next few years, the "new beauty economy" based on science and technology innovation, brand innovation, quality innovation and service innovation will become the biggest highlight in China's tertiary industry.

"I" OPT Product Introduction

OPT Proficiency Therapeutic Instrument Product Introduction

The core technology of OPT repair physiotherapy instrument has three main points: radio frequency + perfect light energy + epidermal cooling, which fully combines the respective advantages of perfect light energy(IPL) and(RF) radio frequency. The selective absorption of light energy by the skin causes the impedance difference between the target tissue and the normal skin, and enhances the absorption of radio frequency by the target tissue under the condition of low light intensity, so that the tissue reaches an ideal temperature rise. The radiofrequency penetrates the skin deeply and does not selectively absorb it, and its conductivity in the skin is closely related to temperature.

1. OPT's advantages:
PT photon depilation is considered to be the most safe, effective, and rapid permanent depilation high-tech technology. The principle of OPT photon depilation is to use a strong pulse light with a wide spectrum of 610-1000 nm, which can be adjusted to a wide range of veins, so it can be different colors. Permanently depilate skin hair from various parts of the body at different depths.

2. OPT effect:
The principle of OPT photon depilation is the use of strong pulse light with a wide spectrum of 610-1000 nm, which can be adjusted to a wide range of veins, so that skin hair can be permanently depilated in different colors and depths of the human body. It is generally believed that depilation is a selective photopyrolysis principle using a patented strong pulse light source. The absorption of light in a specific band by melanocytes in the hair follicle is used to heat the hair follicle and selectively destroy the hair follicle. At the same time, the emitted heat can be transmitted to the depth of the hair follicle through the dry section, and the temperature of the hair follicle increases rapidly, so as to achieve the effect of removing hair while avoiding damage to the surrounding tissues, because the hair follicle is no longer renewable. Therefore, OPT photon depilation realizes the effect of permanent depilation.

OPT Photon depilation Advantages

1, OPT photon depilation technology is purely technically speaking, completely belongs to the best ideal method of permanent depilation. However, human hair generally has three cycles, namely, growth period, stability period, and rest period. Only the implementation of photon technology during the hair follicle growth period can achieve the efficacy of damaged hair follicle cells.

2, OPT photon hair removal is not painful, no epidermal damage, no scars, and will not rebound after hair removal. It has the advantages of safety, no damage, rapid and thorough depilation.
Using IPL and dual-radio frequency technology, it plays a role in the entire dermis and connective tissue, stimulating collagen at different depths, rearranging and growing to achieve a nursing effect, using the selective absorption of light energy by the skin, and making various lesions of the epidermis and dermis. tissue, The photopyrolysis effect is produced. Since the light energy is far lower than the traditional IPL light energy, it can absorb more energy from various pigment and vascular lesions in the epidermis and dermis without damaging the epidermis, and better remove these lesions and achieve nursing effects.

The frequency of RF bipolar frequency emission can cause the water molecules in the cell to vibrate at high speeds within a specific depth under the skin. Through this high-speed rotational friction, heat is generated at 45-60 °C, collagen is constricted, and the skin and wrinkles are immediately relaxed. Tight, Subsequently, the thermal effect produced in the dermis caused collagen to proliferate, rearrange, and increase in number. At the same time, the collagen damaged by aging was repaired to achieve immediate skin tightening and long-lasting wrinkle removal and anti-aging effects.

3, the scope of application:

3.1 Crunch, peel and facial enhancement.
3.2 Deep spot, epidermal spot, dermal spot, senile spot.
3.3 Whitening skin
3.4 Depilation: Excessive hair at different degrees of thickness, shallow and deep.
3.5 Care for acne, removing red blood.

4, equipment inspection

Before booting, please confirm whether the instrument has added water(pure water or distilled water). After booting, the system's circuit immediately enters a self-inspection state. In this case, the operator should allow the instrument to operate for 5 minutes before proceeding with the next operation.

5, equipment level

Electric shock protection: Class 1 BF anti-corrosive liquid: ordinary
Do not use this machine in an environment where there is a mixture of combustible anesthetics and air or nitric oxide. Operation mode: continuous

OPT Standard operating procedures for physiotherapy instrument care:

Before operation, prepare all necessary items for operation, small bowl, scraper, skim cotton, gel.
Use of skinhead care procedures
1, fill out the form
Fill in the customer file form in detail, confirm the nursing project, and ask the customer to fully understand all the things that will appear before and after the care and care should be paid attention to.

2, cleansing
Clean face with a soft cleanser(three minutes). Reminder: Before operation, use the hands and instruments of the new cleaner sterilizer to protect the bald head and ensure the aseptic nature of the operation.

3, Preheat
After cleaning, open the instrument, Preheat the instrument for at least 3 minutes, Preheat the light. Objective: To ensure the safety of operation by making the water in the water pipe fully circulate, so as not to cause the phenomenon of bald firing gun.
4, shave

Scrape off facial excess hair, forehead, eyebrows, two horns, two cheeks, lips and other hair. (2 minutes) Purpose: When the hair is black and the black in the operation absorbs part of the light, the light absorbed by the skin will decrease and the nursing effect will be reduced: the black hair will increase the tingling sensation of the patient during the absorption of light. So shave off the hair to avoid tension; If the hair is not shaved, the small hairs that absorb light will remain in part of the skin's epidermis and may increase the sensitivity of the skin. Therefore, the hair should be shaved.

5, glue
Apply 2-3 mm thick cold gel(2 minutes) evenly in the care area. If you want to do hair removal, you must shave the hair before applying the cold gel.
Effect: Cold gel belongs to the light guide agent, which has the effect of net, cooling and light guide. Cold gels are forbidden to be used repeatedly and discarded after use.
Tabu: Avoid eyes, eyebrows, and lips when applying cold gel. These belong to the forbidden treatment area.

6, eye protection
Patients are required to close their eyes and cover them with wet cotton or professional eye patches.
Effect: Avoid the nurse to see the bright light and stress, play a calming role.

7, try to be sensitive
Adjust safety parameters to make two or three light spots at the root of the ear and observe for three minutes.
Effect: Allergic phenomenon occurs and the error continues to operate.

8, operation
It is suitable for the nurse to perform orderly operation on the parameters. (About 20 minutes)

Note:
8.1 The patient should be advised of mild heat before operation to avoid panic.
8.2 The operation should start from the safety value, while doing the side adjustment, at any time to ask the patient's feelings.
8.3 Light spots should be arranged closely from bottom to top, one-third of a stack, and if the parameters are appropriate,
It is forbidden to repeatedly irradiate a certain area, and the heat accumulated from repeated irradiation can directly cause skin redness and burns;
8.4 The bald head should be applied vertically to the skin. It should not be too tight or leave the skin(called virtual contact). Virtual contact can(avoid) cause severe post-care reactions to the skin.
8.5 During the operation, changes in the skin must be observed at any time. It is necessary to listen to two eyes, one to listen to the patient's feelings of skin tingling, and the other to see the changes in the patient's skin. According to these two points, the parameters are changed at any time. (The parameters to be adjusted for various skin problems are different from the feeling of the patient's skin. See the parameter comparison table for details.)

9, dressing
After the operation, the cold gel will stay on the face for about 20 minutes. If it is reflected after care, the red holding time can be applied with cold water or ice water until it is not red.

10, cleaning
Use cold water to clean the nursing part of the cold gel, smear care after repair products.

10.1 In the care of pigment problems, the first seven days are coated with grass essence and the restoration crystal is 7 days. After seven days, the restoration essence is painted at night. Other skin care products are normal.
10.2 When nursing a general skin problem, apply the restoration crystal 7 days before the first 7 days and the restoration essence 7 days after the night. Other skin care products are normal.

11, course settings
Light wave rapine skin care: 30-45 days/4 times / treatment
Light wave skin depilation care: 20 to 25 days/4 to 5 times / course

12, special reminder

12.1 Before operation, customers are asked whether the skin is sensitive, allergic, whether there is a nursing history and post-nursing response, and fill in the patient file form in detail. Only after fully understanding the skin of the customer can we better master the parameter adjustment. Before operation, the customer must be informed of how they will feel and how their skin will change during care.
12.2 If the cooling water in the instrument case is rapidly heated during continuous operation of the extensive nursing care, if the handle is hot, please immediately suspend the use. You can replace the cold water or allow the water to cool down for care. Otherwise, it will damage the important parts of the instrument.
12.3 The circulating water in the instrument tank is changed once a month or so, and it is necessary to use pure water or distilled water.

13, IPL treatment first parameter value

Nursing orders

Number of pulses

Pulse cycle

First pulse width

Meridian width

Interval discharge

Wide interval discharge

Interval cold

IPL

RF

Remove thick black hair

4T

4S

6.0

6.0

20

2

100-80

10-30

3-4

Shallow hair

5T

3S

6.0

6.0

20

2

100-80

10-30

3-4

Freckle

5T

2S

4.5

3.9

20

4

100-80

20-32

3-4

Tender skin

3T

2S

4.0

4.0

20

3

100-60

20-25

3-5

Red blood

3T

4S

3.0

4.0

20

4

100-60

20-30

3-5

Acne

3T

2S

4.5

5.0

20

4

100-80

20-30

2-4

To crease and ascend

3T

2S

4.0

4.0

20

3

20

0

2-8

Note: The above energy is for reference. The energy at the first operation is slightly smaller than the above energy. Run the speckle test before you operate. Depending on the number of people, they can be added or subtracted. Each addition or subtraction is measured by 2-3 degrees. If the later operation feels insufficient energy, the energy can be adjusted upwards under the reference of the parameter table. Each part is repeated twice at most, and the energy is small enough to be repeated.

14. Filter Selection

alopecia 640-1200nm Filter Selection
Freckle, red blood 530-1200nm Filter Selection
Flesh, wrinkle, lift. 480-1200nm Filter Selection

OPT safety precautions for physiotherapy operation

1. The operation of the note
Remember that when the treatment head needs to leave the skin, release the treatment switch before leaving the skin.(If you press the switch at the same time, treat the head to leave the skin, which may cause skin burns to the customer. ). You need to adjust your energy according to your customer's sensitivity.
When the operation, the treatment head should be close to the skin, the hand should press the treatment button. Treatment of the head should be perpendicular to the surface of the skin, not inclined to the surface of the skin
The head treatment must be coupled with glue
When it comes to sensitive areas such as cheekbones or eye circumference, be light. The treatment head only needs to be lightly attached to the skin.
Each site is repeated 3 to 4 times at most.
It is forbidden to spray alcohol directly to the head of the treatment for disinfection.
When operating, the energy selection is weak to strong, the energy is high, and the effect is good. The standard is called the maximum tolerance within the range.
It is strictly forbidden to operate in the throat, eyeball, Temple, nose, etc..
When operating, thin skin and vascular distribution areas should be carefully operated
After the operation, the skin of some guests is a normal phenomenon. After half an hour, they automatically fade red.

2. Safety of instruments
OPT Restoration Physiotherapy is a high-tech medical device that is used to safely and reliably remove various facial defects and excess hair from various parts of the body. Trained qualified practitioners can safely use the machine as long as it is properly operated and maintained. Operators or other paramedical personnel operating or maintaining shall be fully aware of the safety information provided in this chapter. The main consideration is to consider the safety of the person under care, the hand nurse, and other personnel. The safety of the person being cared for and the operator has been considered to the maximum extent in the design of the light wave skin. The following are some of its security measures:
After booting, the instrument self-inspection system is started immediately. During the operation of the equipment, the system will continuously detect the circuit.
The pulse light can only be emitted from the front surface of the guide crystal, which is transported to the patient's skin using a closed filter / guide crystal.
This machine is designed to have an independent safety circuit that can be cut off when the strong light energy is too large.
In case of emergency, the power can be quickly cut off through the red emergency switch.

Warning about bright light

Strong light may damage the eyes and cause fire or Burns, and all necessary protective measures should be taken when used.
Excessive emission of light energy to the care site may cause thermal damage to the skin, resulting in hyperplasia or abnormal pigmentation.
Even if you wear a protective mirror, you must not look directly at the strong light emitted from the light care head.
Do not point the head of light care into the air. When not in use, the head of care should be placed on the hook, and the nursing should point to the hand care site.
Electrical and mechanical safety
Keep all panels and covers closed and opening them can be dangerous.
There is a dangerous high voltage in the device, and even after the power cord is disconnected, some parts may still store electricity. Therefore, no part of the cover plate shall be removed except by our technical personnel.
When maintaining the equipment, do not turn on the power, open the cover or leave the equipment unattended.
This machine is well balanced and movable, but it can only be moved slowly and carefully. Special care is taken not to drag the instrument with the care head.
This machine is grounded through the ground line in the three-core power supply. Good grounding is very important for operation safety.
The temperature rises after the object absorbs light energy. Precautionary measures should be taken to reduce the risk of inflammable substances in or near the ignition care area.
Do not use flammable substances such as alcohol or acetone when performing pre-care skin treatment. If necessary, use soapy water or medical distilled water.
If alcohol is used to clean the bald head or sterilize any part of it, it must be thoroughly dried before it can work.

Notes on taboos

The following people are not suitable for care using this instrument:
1. Pregnant women hypertension, heart disease, diabetes
2. People who are allergic to light are forbidden to do it
3. There is an open wound part
4. Can not avoid the bright light in the near future
5. No breast enhancement during menstruation
6. Is using efficacy products should stop for 1 to 3 months for care
7. Above the skin scars, birthmarks, moles

Operational considerations

Observe the skin condition of the customer and the color of the spot. According to the customer's ability to withstand and skin metabolism, the energy is slightly lower when the first time it is done, and it can be done twice more. Try not to scab guests the first time. The second time you can first communicate with the guests and discuss it well. After the guests are ready for psychological preparation, the energy is adjusted upwards. And advise good postoperative care.

Post-operation care

1. Sun protection, strengthen water supply
2. Gaga or bubble is waterproof.
3. Red and swollen as far as possible to reduce the temperature of the epidermis, you can use cold spray, ice, etc.
4. Eat less sensitive food.
5. Do not apply any potency or hormone products during treatmenttreatment 

Techniques

1. For safety reasons, lower energy is always used above the bone(eg, forehead, temples, cheekbones, etc.);
2. Close the treatment head to the skin surface to ensure that the electrode is in full contact with the skin;
3. Reduce RF energy by 40 % if the electrode is not in full contact with the skin(eg, nose)
4. Do not treat the eye sockets. Stretch the peripheral part of the eye to the top of the bone for treatment.
5. When repeating the same area, there is a minimum interval of 30 seconds between each treatment;
6. Pigmentation does not affect the setting of parameters and the effect of treatment;
7. Some customers or some areas can achieve the desired effect with only one treatment, and some even require multiple treatments.

Points for attention after care

1. Do not use whitening to stimulate utility products
2. No hot water, no sauna for seven days
3. Do not eat irritating and pigmented foods such as chocolate coffee for seven days; Tobacco and alcohol
4. Attention to sun protection: patients should use SPF15 sunscreen and sunscreen within one month after surgery, go out to pay attention to umbrellas and sun caps, and do a good job of sun protection. Because the sun exposure may increase the reproduction rate of melanin, resulting in excessive pigmentation.
5. Do not scratch with your hands if there is scab
6. After 10 days of water treatment
7. Makeup: Do not make up immediately after surgery in order to make the effect more obvious. The cosmetics used a few days after the operation are best not to use chemical preparations, and biological skin care products are not suitable for the use of powdered cosmetics. If there is redness and swelling exudation in the treatment area, the doctor should be notified immediately and the makeup should be stopped. Proper administration of some VitC, VitE drugs.
8. According to normal physiological processes, customers should undergo the next treatment after 3-4 weeks, a course of treatment 4-6 times. After a course of treatment, the defects of the treatment site, such as red blood filaments, daylight spots, and senile spots, are basically solved. At the same time, the skin becomes delicate and shiny.
9. Note: Due to personal physical differences, individual customers can experience temporary discomfort, vesicles, pigmentation, redness, bruising, and suggested that the ice bag should be applied for 30 minutes after surgery, and makeup can be used only 5 days after treatment.

Method of operation and function of the instrument

1. Welcome interface
Turn on the device's total power switch. The screen shows the welcome interface. As shown in Figure 1, the touch screen enters the therapeutic mode selection interface.

hm06

2. OPT treatment interface

hm07

3. SHR treatment interface

hm08

Pulse seeing energy: 6-8MS. Frequency: 4-5 Energy: 15(Due to the different energy received by the customer, it can be adjusted upwards.

4. An example of OPT Freckle treatment interface(because the same is true for other projects)

hm09

1, the first pulse width energy mind:(6.0-8.0)
2, sub-pulse width energy mind:(5.8-7.9)
3, repeat pulse width energy mind:(5.7-7 .8)
Note: When adjusting, please note: The first pulse width should be larger than the second pulse width, and the second pulse width should be larger than the repeated pulse width.
4, the first pulse interval: mind(20)
5, sub-pulse interval: mind(20)
6, RF extension: 300-500
7, exit interval: 2-3
8, Pulse number: 5
When adjusting IPL and RF energy, click on an IPL or RF word mark first. When the word is highlighted, the energy can be adjusted: IPL energy is generally adjusted from 15, and RF energy is about 3-5.

"I" laser introduction

1. Security rules

1.1. Please do not dismantle this instrument or perform other operations without authorization. All maintenance work should be performed by professionals.
1.2. Please do not disassemble this instrument in a place where there is water or in a wet place. Be careful not to wet the instrument.
1.3. Please pull the power plug and contact the professional service station if you encounter the following situation.
A. Instrument wet water
B. Instruments have an abnormal smell, smoke, or sound and noise.
C. The wiring's broken.
D. Instrument crash
1.4. Please don't pile up the clutter on the wires and wiring. Don't put the instrument where people can step on wires and wiring.
1.5. For your safety and that of others, use the power plug and pull it out.
1.6. Please do not put debris into the instrument outlet, otherwise it may cause fire or electric shock. If something enters the instrument, please do not take it out in person and contact our company or dealer immediately.
1.7. Please do not put the instrument in an unstable position so as not to damage the roll.
1.8. The Company has the right to amend this specification without notice! And reserve the right of final interpretation of the above content.

2. Operational specification

Please read the following carefully before operation.
2.1. It is important to make different settings according to the need for specific treatment!
2.2. Use this instrument should not have pain, cause skin redness, or leave a mark.
2.3. Please move slowly on the face or body skin to treat the head. Do not let it stay at one point.
2.4. Please do not treat children under the age of 7 with this instrument. Children over 7 years of age need the advice of a doctor to use this instrument for treatment.
2.5. If the customer has fever, inflammation, dermatitis(acne, eczema, herpes), symptoms of wart, exposed or recently sewn wounds, and serious positive diseases(cancer, AIDS, hepatitis, blood diseases, blood clotting problems, etc.), phlebitis, The last two months have done vascular surgery, varicose veins, limb stings do not use this instrument to treat. If you have any other concerns, please consult your doctor.
2.6. Please do not treat pregnant women with this instrument.
2.7. This instrument is suitable for external use and healthy parts, except eyes, throat, ears, glottis, and genitals.
2.8. Never use in the oral cavity, mucous membranes, nipples or moles not recommended by a doctor.
2.9. This instrument must not be used for epilepsy patients and mental patients.
2.10. Consult a doctor or beautician for long-term medication(anti-allergy, anticoagulant, antibiotic) or for minor bruising due to impact.
2.11. Please remove items such as jewelry rings and use this instrument for treatment.
2.12. Regular use of this instrument can extend its service life. It is best not to idle the instrument for long periods of time. Failure to follow the instructions and recommendations for use does not have the desired effect. The use of the instrument should not exceed the recommended time.
2.13. If your symptoms aren't improving or you have any questions about use, consult your doctor.
2.14. The effect will vary according to age, lifestyle(physical activity level, diet, etc.).
2.15. The instrument can only be used by customers who have undergone cosmetic surgery if they follow the surgeon's advice.
2.16. The instrument is used only by professionals and is forbidden to any individual.
2.17. The continuous operation of the instrument can not exceed two hours. It is best to stop the electricity for 10 to 15 minutes per hour of work.

3. Principles of laser therapy

3.1 Laser system
The laser pigment treatment system uses the Gemstone Q mode, and the laser instantly emits high energy to effectively break the color base in the diseased tissue, that is, the photoinduced blasting principle: the laser accumulates high energy instantaneous emission. The laser at wavelengths of 1064 and 532 nm instantly reaches the pathological discoloration group in a very short period of time(pulse width is about 10-20 NS), and the corresponding color group absorbs light energy from the thermal rapid expansion and instantly bursts, and part of the(epidermis) color group breaks. After the epidermis metabolism, Some of the chromatids(in tissues below the epidermis) are fragmented into tiny particles that can be swallowed by macrophages. After being digested by macrophages, they are eventually excreted through the lymphatic circulation of the human body, and the chromatid of the diseased tissue will gradually decrease until it disappears. The surrounding normal skin tissue has almost no damage because it does not absorb laser wavelengths of 1064, 532 nm. Since the passive Q laser can not adjust the single pulse energy and can only adjust the number of pulses, it is easy to cause post-operative heat damage and slight scars.
3.2. Advantages of the laser system
1) Using the Gemstone Q mode, the pulse width is about 10-20ns;
2) patented ceramic diffuse reflection gun body with good stability in use;
3) Dedicated YAG crystals(excellent grades), single pulse energy up to 200mj, multi-pulse energy up to 1200mj; The 532nm laser head removes the red base, the 1064 laser head removes the black base, and the black-faced doll treats the head whitening and tender skin(with toner treatment);
4) High-quality accessories such as special pulse laser Xenon lamps and high-power pumps ensure the quality and continuous work of the instrument.
3.3 Scope of application of the laser system:
It is mainly used to eliminate some endogenous pigmented skin lesions, exogenous pigmented skin problems and traumatic pigmentation.
1) Endogenous pigmented skin lesions: Ota mole, Ito hemorrhoid, Mongolian spot, brown blue spot, coffee spot treatment has certain difficulties requiring multiple treatment and repeated treatment and poor postoperative satisfaction. Seborrheic keratosis, spot mole, junction mole, melanosis, blue mole, pigmentation after inflammation, and some chloasma.
2) Exogenous pigmented skin problems: The treatment of pigmented skin lesions such as tattoos, eyebrows, eyeliner, lip lines, and traumatic tattoos has a good clinical effect
3.4 Introduction of Laser Accessories

Remove the red base

532 nm crystal

Remove black base

1064 nm crystal
Use with toner to whiten skin

 Black-faced doll head

4. Standard operating procedure for laser treatment machine:

4.1. Preparation phase:
1) Choose a care project: Choose a suitable care project according to the customer's skin condition and needs.
2) Customer file registration: fill in customer file information in detail, take photos and archive before treatment, establish customer personal data files, and confirm treatment projects.
3) Treatment site planning: The treatment plan should be focused on the specific conditions of the client's skin.
4) Introduction of treatment plan: The customer is introduced to the care plan in detail, so that the customer has a complete understanding of the skin before and after care, all the things that will appear to reflect and should be noticed after care.
5) Tool preparation: All necessary items for operation before operation: small bowls, scraper, skim cotton, gel, alcohol cotton, and equipment use care accessories.
6) Cleaning treatment site: thoroughly clean the skin and keep the skin dry; And to beautician hands and instruments nursing skinhead disinfection, ensure the operation of aseptic.
(Note: Before treatment, all metal items such as rings, wristwatches, necklaces worn by customers should be removed)
7) Connect and check the instrument: Connect the instrument power supply and various accessories. The LCD screen on the panel is extinguished. The tank is filled with water with a funnel. After checking, it enters the working state.

4.2. Treatment stage:
1) Boot: Turn on the instrument power switch, the instrument display is bright, and the system's circuit is immediately self-checked. In this case, the operator should allow the instrument to operate for 5 minutes before proceeding with the next operation.

Note: If you turn on the power switch and the display is still in a state of extinction, please check if the emergency switch is reset. Rotate the emergency switch in the right direction to reset the emergency switch. At this time, the instrument enters the standby state.
2) Preheat: Preheat instrument for at least 3 minutes, Preheat does not turn on the light.
Objective: To ensure the safety of operation by making the water in the water pipe fully circulate, so as not to cause the phenomenon of bald firing gun.
3) Cuisine: Scrape off excess facial hair, forehead, eyebrows, horns, cheeks, lips and other hair. (two minutes)
Objective: The hair is black, black will absorb part of the light in the operation, then the light absorbed by the skin will be reduced, which will reduce the nursing effect; Black hair absorbs light and increases the tingling sensation of the person receiving care, so shave the hair; If the hair is not shaved, the small hairs that absorb light will remain in part of the skin's epidermis and may increase the sensitivity of the skin.
4) Coating or toner: Black face doll care smear toner.
(a) When working on the Black Face Doll Project, it is necessary to apply powder for the Black Face Doll.
5) Test sensitivity: Adjust safety parameters to make two or three light spots at the root of the ear and observe for three minutes.
Effect: Allergic phenomenon occurs and the error continues to operate.
6) Operation: The adjustment is suitable for the patient to perform orderly operation of the parameters. (About 20 minutes)
7) Casting face: If the reaction after nursing is large, the red holding time can be longer and can be covered with cold water or ice water until it is not red.
8) Cleansing: Post-smear Care Repair Products
(a) For the treatment of pigment problems, the first 7 days are covered with herbal essence and the restoration crystal 7 days. After 7 days, the restoration essence is painted at night. Other skin care products are normal.
(b) For general skin problems, 7 days for the first 7 days for the restoration of crystal, and 7 days for the evening for the restoration of essence. Other skin care products are normal.
Note:
A) Ask customers before operation: whether the skin is sensitive, allergic, whether there is a nursing history and post-nursing response, fill in the patient file form. Only after fully understanding the skin of the customer can we better master the parameter adjustment. Before operation, the customer must be informed of how they will feel and how their skin will change during care.
B) The patient should be informed of a slight tingling sensation before operation so as not to panic.
C) The operation should start with the safety energy value, ask the patient's feelings, and adjust the appropriate energy according to the customer's feelings.
D) During operation, the spots are closely arranged from bottom to top, one third of one stack, and when the parameters are appropriate, repeated irradiation of a certain area is prohibited. The heat accumulated from repeated irradiation may directly cause skin redness and burns;
E) short distance customer skin 3-5 cm in front of the laser head when operating.
F) During the operation, you must always observe changes in the customer's skin and listen to the patient's sensation of skin tingling. According to these two points, the parameters are changed at any time. (The parameters to be adjusted for various skin problems are different from the feeling of the patient's skin. See the parameter comparison table for details.)
G) If the cooling water in the instrument case will rapidly heat up during continuous operation of the extensive disease care, if the handle is hot, please immediately suspend the use. You can replace the cold water or allow the water to cool down for care. Otherwise, it will damage important parts of the instrument.

5. Operational safety precautions

Remember that when the treatment head needs to leave the skin, release the treatment switch before leaving the skin.(If you press the switch at the same time, treat the head to leave the skin, which may cause skin burns to the customer. ). You need to adjust your energy according to your customer's sensitivity.
When the operation, the treatment head should be close to the skin, the hand should press the treatment button. Treatment of the head

6.  laser treatment

Eyebrows:
It is recommended that the eyebrows be shaved before surgery, and the new eyebrows are 2 to 4 circumference after washing the eyebrows. The gun is stable and the muzzle distance is 1.5 to 2 cm from the skin. The angle of the gun inclination should not be too large. From the tail of the eyebrows, the spots are evenly superimposed.
Wash eyeliner:
Washing eyeliner must use blepharograph. Before the eyelid plate is used, 75 % alcohol is used for double-sided disinfection and erythromycin eye ointment is applied on both sides. Insert between the eyelid and the eyeball, do not press down on the eyeball.
The eyeliner generally needs more than 2 treatments, and the treatment interval can not be less than 1 and a half months.
Narcotic drugs may be used for people with severe pain.
Tattoos:
Similar to eyebrow washing, the muzzle is about 3 to 4 cm away from the skin. The reverse color may appear after the first treatment, and the reverse color part can be treated for the second time after half an hour.
In the treatment, the skin appears to be swollen, blister, bleeding, and deep redness.
Notes:
In treatment, never look directly at the light source
After treatment, it is forbidden to paint eyebrows and wash them on 3-7 days.
Watch out for sun protection.
It is forbidden to eat spicy, seafood and other stimulating foods.
Those with more bleeding and severe swelling take anti-inflammatory drugs, or take drugs as prescribed by the doctor.
Application of erythromycin eye ointment or aloe ointment for skin repair at the site of the lesion

7. Operation interface:

Main Interface:

hm06

Press the work key and step on the pedal switch to treat.
Release switch suspended.                                      

8. Maintenance, repair

The equipment is mainly composed of precision optical instruments or electronic instruments. Its maintenance and repair shall comply with the general provisions of precision optical and electronic instruments. The cooling water in the tank must be replaced every 3000 points to prevent the energy from decreasing. In storage and use, we must strictly prevent bumping, squeezing and vibration. It is recommended that after each treatment, check whether the lens surface has spatter attachment, and if so, gently wipe the head with mirror paper or cotton swabs dipped in anhydrous alcohol.