Welcome To HONDEE

Original Factory Legs Hair Removal - 4D HIFU – Hondee

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Lazer Hair Removal, Hair Remover, Skin Rejuvenation Machine, We glance forward to receiving your enquires shortly and hope to have the opportunity to function along with you inside the future. Welcome to acquire a glimpse at our organization.
Original Factory Legs Hair Removal - 4D HIFU – Hondee Detail:

Instrument Overview

Our new latest product 4D multi-line ultrasonic beauty instrument can achieve three perfect effects of skin tightening, wrinkle removal, shaping body.The most advanced part of the 4D multi-line ultrasonic beauty instrument is the use of the most advanced ultrasonic energy, which can penetrate deep into the SMAS layer of the skin, causing immediate contraction of collagen and stimulating collagen fiber network, thus enhancing skin elasticity from the bottom layer (the self-repair mechanism is safer).This is the safest and most effective way to treat facial skin aging and sagging in the beauty industry.It is a cross-era multiple beauty instrument without wound, convalescence, bleeding . 4D multi-line ultrasonic beauty instrument ,the magical removing wrinkles and improving efficacy has been recognized by the authoritative institutions in the United States, and is known as the miracle of youthful youth!

Instrument Principle

th10

Technology Advantage

1. Two modes: fast mode or slow mode can be switched.

2. A maximum of 11 lines can be used in a single shot, and the maximum energy area is 10mm wide. the corresponding parameters can be adjusted according to the size of the skin area,which make the operation time is greatly shortened, make the energy point effects on the skin is more uniform, and the curative effect is better.

3. Using the most advanced high-tech technology, it is equipped with two treatment heads according to the facial skin condition,which accurately affects different depths of skin, and the energy is slightly over the epidermis during treatment, and 100% without any damage.at the same time,

At the same time, the depth of the skin treated by the treatment head is consistent with the set value, ensuring the customer’s painless and comfortable.

4. In addition to the thermal effect on dermal collagen and collagen fiber, it also has thermal stimulation on the fat layer and fascia layer (SMAS), and the therapeutic effect is far better than that of Thermage.

5. The operation is simple and convenient, no need for consumables, greatly reducing treatment costs.

6. The effect of tightening and shaping can be seen immediately after treatment, which can last for at least 18-24 months at a time, and achieve negative growth for skin age once a year.

7. Makeup immediately after treatment does not affect normal life and work.

Name of Instrument Parts

4d11

Functional Profile of Therapeutic Head

th1

Remarked: The following probes for body: 16mm, 13mm, 10mm, 8mm, 6mm, the corresponding probe can be selected to treat body parts according to the needs.

Installation of Instruments

Insert the handle line into the socket at the right side of the machine and fix the screws, plug the power cord into the left power socket and connect to the power supply line suitable for the voltage within the normal operating range of the instrument. The installation of the probe is shown below.

d2

Interface Introduction

1. Start-up

Check whether the connection of the instrument is normal, switch on the power of the instrument and press the power switch of the host, the machine will start up and the boot interface appears. (picture as below)

D422

After clicking the boot interface, it automatically enters into the professional work interface(pictures as below).

d424

2. Function introduction of professional work interface.

th2
th3
4d12

▲The above is the recommended energy value for each part of each probe’s operation. (If the guests can also bear can also be adjusted accordingly ,It is appropriate for the guests to feel no stinging pain.)

Operational exclusion zoneAvoid hairline, temples, eyes (eyeballs), Yintang, nose, upper lip, chin, larynx, aorta, and navel.

Operational Steps of the Instrument

1. Before using the instrument, disinfect and wipe the probe with alcohol to dry the facial water.

2. Apply the product gel (photosensitive gel) evenly to the area to be treated.

3. Before the operation of the instrument, replace the required treatment head and adjust the energy from low to high to the range that the experiencer can withstand.

4. During the operation, the treatment head should be kept flat against the skin, and the operation spacing should be arranged closely.

5. In the process of operation, we should constantly ask the experiencer about comfort and adjustment of energy size to ensure that the experiencer receives the experience in a pleasant state.

6. Repeated intensive treatment at the problem site (2-3 times).

Setting and Treatment Reference

  Width  Clearance Power Pitch Length

Problematic skin

Severe skin

Normal skin 8-10

1.5-2.0

0.4-1.2

1.3-1.8

05-25

3times/course of treatment

1 time/2-3 months5 times/course of treatment
Sensitive skin

1-10

1.8-3.0

0.3-1.0

1.5-2.0

05-25

Precautions and Maintenance

1. After using the instrument each time, please wipe it with clean water, disinfect it with alcohol and keep it properly(Avoid scratching the black film of the probe).

2. The plug with grounding pin must be used before use, and ensure that the power socket of the instrument is truly grounded.

3. Please make sure that the voltage of instrument is adapted. If the local power supply voltage is unstable, we recommend that the user increase the power matching power supply.

4. In order to ensure the therapeutic efect and normal service life of the instrument, please use the specified accessories provided or recommended by the original manufacturer.

5. Do not place in a humid place or near a water source, and do not expose the instrument directly to the sun.

6. Do not place the instrument close to a strong heat source as this may affect the life of the instrument and its normal use.

8. To avoid poor contact during winter or dry weather, please apply the gel to the face evenly (the probe should be pressed flat).

9. Media such as water, oil shall not infitrate into the inside of the instrument. It shall not be hit, knocked or slammed to avoid damage to the instrument.

10. After using the ultrasonic beauty instrument, please disinfect the probe with alcohol in time and disconnect the power supply.

Contraindication of Instrument Users

The Patients with the following symptoms should be cautious in using the device. Please consult doctors or professionals before using the device. The details are as follows:

1. Before using the instrument, the skin of the physiotherapy part should be cleaned to prevent the dirt from entering the skin with ultrasonic waves or preventing the penetration of ultrasonic waves. Please remove all metal objects from your body before treatment to avoid unpredictable conditions and affect the efficacy.

2. It is better to use a certain viscosity of the medium, which is conducive to the better integration of ultrasound and skin, and to prevent the gap from causing reflection, which is not conducive to better transmission of sound energy.

3. Each treatment area should not be repeated too much, up to three times, to avoid skin redness and swelling.

4. The degree of heat of the probe does not represent the output of the ultrasonic power, the water liquid with a small concentration or drug should not be directly infiltrated, otherwise it may cause dry skin.

5. The probe should not be close to the eye or pass through the eyeball when using the instrument.

6. The instrument should also be used with caution by patients who are ill unless the doctor’s permission is obtained.

7. Patients with malignant tumors, hemophilia or severe bleeding

8. Patients with major diseases and who with skin diseases and infectious diseases should be used with caution.

9. Heart, brain, neck nerve center, spine, eyeball, bleeding, injection.

10. Pregnant women, severe heart disease, diabetes, hyperthyroidism, and high blood pressure.

11. The treatment of Ultrasonic beauty instrument can only be performed after half a year of injection of hyaluronic acid.

12. After treatment, do not eat spicy food, and do not wash your face with superheated or supercooled water within a week. no hot yoga, sauna, steamed face and facial massage (Avoid squeezing the face), apply mask for hydration every day for a week, and pay attention to sun protection, what’s more, do not use the RF and light instrument for treatment within a month.

Instrument Maintenance

1. After using the instrument, please clean it with alcohol disinfection and keep it properly.

2. The plug with grounding pin must be used before use, and ensure that the power socket of the instrument is truly grounded.

3. Please make sure that the voltage of instrument is adapted. If the local power supply voltage is unstable, we recommend that the user increase the power matching power supply.

4. In order to ensure the therapeutic efect and normal service life of the instrument, please use the specified accessories provided or recommended by the original manufacturer.

5. Do not place in a humid place or near a water source, and do not expose the instrument directly to the sun.

6. Do not place the instrument close to a strong heat source as this may affect the life of the instrument and its normal use.

7. Please first remove all metal objects from your body to avoid unpredictable conditions and affect the efficacy.

8. In order to avoid contact failure, please pay attention to the skin contact with a certain degree of moisture, with water-based products or water to wipe it can achieve the desired effect

9. When not in use, please turm off the power switch of the instrument, and ensure that the total power of the instrument is turned off after use to ensure the safety of the electrical products.

10. Using instruments or training instrument operators in strict accordance with instructions in the use manual.

Technical Parameters and Package Size


Product detail pictures:

Original Factory Legs Hair Removal - 4D HIFU – Hondee detail pictures

Original Factory Legs Hair Removal - 4D HIFU – Hondee detail pictures

Original Factory Legs Hair Removal - 4D HIFU – Hondee detail pictures

Original Factory Legs Hair Removal - 4D HIFU – Hondee detail pictures

Original Factory Legs Hair Removal - 4D HIFU – Hondee detail pictures


Related Product Guide:

Using a full scientific good quality administration system, very good quality and superior faith, we win good standing and occupied this discipline for Original Factory Legs Hair Removal - 4D HIFU – Hondee , The product will supply to all over the world, such as: Mali, Atlanta, Egypt, With good quality, reasonable price and sincere service, we enjoy a good reputation. Products are exported to South America, Australia, Southeast Asia and so on. Warmly welcome customers at home and abroad to cooperate with us for the brilliant future.
  • The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Juliet from Moscow - 2018.12.25 12:43
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Kelly from Czech - 2018.06.28 19:27
    Write your message here and send it to us